{
  "status": "CLOCK_INTERVAL_PASS_CONDITIONAL_HARDWARE_HOLD",
  "physical_promotion": 0,
  "lane": "development; no registry entry",
  "independent_review": "PENDING",
  "experiment": "NONE",
  "sources_accessed_UTC": "2026-10-21",
  "sources": [
    {
      "id": "H193",
      "url": "https://www.hammfg.com/electronics/transformers/choke/193",
      "facts": "193S: 1H,5.75ohm;15% series tolerances; L measured at rated DC current.",
      "status": "SUPPLIER_SCREEN_NOT_OPERATING_BAND_CERTIFICATE"
    },
    {
      "id": "NUES",
      "url": "https://www.nichicon.com/en-us/part/ues1c102mhm/5398/",
      "series_url": "https://www.nichicon.com/getmedia/069aeeb2-784e-41be-9621-207263576a6d/e-ues.pdf",
      "facts": "UES1C102MHM: bipolar1000uF;20% capacitance tolerance at catalogue conditions;480uA leakage limit under rated-voltage test.",
      "status": "SUPPLIER_SCREEN_NOT_LOW_VOLTAGE_LEAKAGE_CERTIFICATE"
    },
    {
      "id": "A4630",
      "url": "https://www.analog.com/media/en/technical-documentation/data-sheets/ad4630-24_ad4632-24.pdf",
      "revision": "B",
      "facts": "AD4630-24: dual24bit;2MSPS/channel maximum;300ns maximum conversion time under conditions.",
      "status": "PIPELINE_AND_NOISE_TAILS_OPEN"
    },
    {
      "id": "A5791",
      "url": "https://www.analog.com/media/en/technical-documentation/data-sheets/AD5791.pdf",
      "revision": "F",
      "facts": "24bit write frame;35MHz maximum write clock; settling depends on step/buffer.",
      "status": "ACTUATOR_MODEL_OPEN"
    }
  ],
  "clock": {
    "lower_strict_seconds": "8/575",
    "upper_seconds": "1/48",
    "example_seconds": "1/60",
    "prefix_duration_seconds": "1/6000"
  },
  "operating_band_premises": {
    "L_min_H": "17/20",
    "C_min_F": "1/1250",
    "R_max_ohms": "529/80",
    "status": "OPEN; catalogue screening does not prove these at actual bias or during transient"
  },
  "physical_plant": "Phi_dot=Q/C-(R/L)Phi+V; Q_dot=-Phi/L+I; actual unmodeled terms bounded separately",
  "scales": {
    "nominal_Q0_C": "1/10000",
    "nominal_Phi0_Wb": "sqrt(10)/1000",
    "common_action_J_s": "sqrt(10)/10000000",
    "rule": "After calibration choose per-channel balanced gains with the same action; no reuse of unequal action products"
  },
  "timing": {
    "ADC_proposed_sample_period_s": "1/2000000",
    "command_period_s": "1/1000000",
    "additional_true_input_to_command_latency_s": "<=1/500000",
    "identified_actuator_time_constant_s": "<=1/1000000",
    "independent_endpoint_clock_radius_model": "1/100000",
    "status": "PROPOSED_NOT_MEASURED",
    "DAC_reason": "A24bit frame at35MHz exceeds500ns, so command update is1MHz rather than2MHz"
  },
  "mathematical_results": {
    "local_target_L": "4",
    "actual_speed_bound": "8/5",
    "Gauss_L": "4",
    "tracking": "53/25000",
    "total_residual": "481/50000",
    "residual_slack": "19/50000"
  },
  "accuracy": {
    "input_nu": "3/100000",
    "complete_command_q": "1/25000",
    "actuator_distortion": "1/100000",
    "static_residual_p": "3/400",
    "initial_e0": "1/10000",
    "endpoint_m": "1/10000",
    "status": "SUPPLIED_BOUNDS_NOT_OBSERVATIONS"
  },
  "startup": {
    "zero_initial_actuator": true,
    "hold_radius": "1/20000",
    "preload": "at least10timeconstants;10us in example",
    "tracking_upper": "33/40000",
    "required": [
      "every used sample history in hold tube",
      "reconstructed inputs in D",
      "prehistory speed bound",
      "release kick bound",
      "holding work record"
    ]
  },
  "noise_gate": {
    "controller_input_count_max": 10000,
    "deterministic_input_allowance": "6ppm",
    "noise_allowance": "24ppm",
    "marginal_tail_premise": "two-sided subGaussian scale <=4ppm for every input error",
    "family_failure_bound": "<1/500",
    "status": "OPEN; not inferred from supplier RMS or SNR",
    "other_uncertainties": "Separate joint allocation required for calibration, endpoints, clocks and witnesses"
  },
  "critical_identification_gates": [
    {
      "gate": "Flux/current law",
      "status": "OPEN",
      "records": [
        "inductance at operating bias and transient spectrum",
        "hysteresis and cross-coupling",
        "resistance versus temperature",
        "state reconstruction uncertainty"
      ]
    },
    {
      "gate": "Capacitor state and leakage",
      "status": "OPEN",
      "records": [
        "charge-voltage relation including ESR and memory",
        "actual low-voltage leakage or compensation residual",
        "loading and uncertainty"
      ],
      "nominal_whole_p_current_allowance_A": "45/1000000",
      "warning": "Published480uA rated-voltage limit cannot certify45uA allowance; do not extrapolate linearly to test voltage"
    },
    {
      "gate": "Timing and actuation",
      "status": "OPEN",
      "records": [
        "parallel ADC and DAC architecture",
        "all timestamps and skew",
        "code evaluation and write/latch timing",
        "actual first-order residual",
        "glitches tails range and slew"
      ]
    },
    {
      "gate": "Metrology and review",
      "status": "OPEN",
      "records": [
        "traceable gains offsets references and drift",
        "qualified noise-tail model",
        "independent coupling/work sensing",
        "joint coverage accounting",
        "attributable non-constructor adversarial review"
      ]
    }
  ],
  "scope": "Only the specified short preparation prefix; no full campaign, SDW admission or physical/GUT bridge"
}
